基于碳化硅(SiC)高性能中子探测系统中微弱信号处理需求,设计了一款SiC中子探测器读出电路。该读出电路对SiC中子探测器输出的微弱信号进行读取处理、放大成形,与前端探测器和后端计数器构成一个中子探测系统,可以实现对中子探测计数的需求。设计的读出电路集低压电源管理模块、前置放大器、主放大器、甄别器于一体。通过实验测试验证了电路设计的有效性,测试结果表明:该读出电路工作时单板功耗约为300 mW,等效输入噪声约为1 fC,其中前置放大器线性度为99.72%,输出动态范围约为±3 V,总放大模块增益约为19.28 mV/fC。设计的电路具有低噪声、低功耗、高增益和稳定性好等特点。
Based on the weak signal processing requirements of silicon carbide (SiC) high-performance neutron detection system, a low-noise and low-power SiC neutron detector readout circuit is designed. The readout circuit reads, shapes and amplifies the weak signal output by the SiC neutron detector, and forms a neutron detection system with the front-end detector and the back-end counter, which can realize the needs of neutron count measurement. The designed readout circuit integrates a low-voltage power management module, preamplifier, main amplifier and discriminator. In order to verify the effectiveness of the circuit design, the readout circuit is experimentally tested. The test results indicate that the single board power consumption is about 300 mW, the equivalent input noise is about 1 fC, where the preamplifier linearity is 99.72%, the output dynamic range is about ±3 V, and the total amplification block gain is about 19.28 mV/fC. The designed circuit has the characteristics of low noise, low power consumption, high gain and good stability.
[1] 吴健.基于4H-SiC的中子探测技术研究[D].绵阳:中国工程物理研究院,2014.
[2] NAVA F, CASTALDINI A, CAVALLINI A, et al.Radiation Detection Properties of 4H-SiC Schottky Diodes Irradiated Up to 1016 n/cm2 by 1 MeV Neutrons[J]. IEEE Transactions on Nuclear Science, 2006,53(5):2977-2982.
[3] 吴国斌,赵金龙,刘士兴,等.CZT探测器前端读出电子学设计[J].核电子学与探测技术,2022,42(4):699-704.
[4] 孙文,千奕,苏弘,等.一种新型低噪声大动态范围小型前端电路的研制[J].原子核物理评论,2015,32(2):202-207.
[5] 辛昊,蒋开明,王敏,等.高阶核脉冲信号成形方法研究[J].核电子学与探测技术,2022,42(4):705-711.
[6] 樊磊,魏微,王铮,等.硅像素探测器读出芯片的设计[J].原子能科学技术,2016,50(7):1296-1300.
[7] 蒋俊国,马毅超,李秋菊,等.高计数率时间测量读出电子学系统设计[J].核电子学与探测技术,2022,42(6):1123-1128.
[8] 苏杭,封常青,郑其斌,等.一种低噪声电荷灵敏前置放大器的研制[J].核电子学与探测技术,2015,35(9):857-860.
[9] WANG Y F, SUN Z J, ZHOU J R, et al. Simulation study on the boron-coated GEM neutron beam monitor[J]. Science China Physics, Mechamics and Astrohomy, 2013,56(10):1897-1902.
[10] CHAUDHARI P, SINGH A, TOPKAR A, et al. Fabrication and characterization of silicon based thermal neutron detector with hot wire chemical vapor deposited boron carbide converter[J].Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2015,779(11):33-38.
[11] 杨强,刘军,翟娟,等.Multisim在核电子学虚拟仿真实验中的应用[J].实验室研究与探索,2018,37(5):91-94.
[12] 张怀强,吴和喜,宁洪涛.基于Multisim的核信号仿真与高斯成形研究[J].核电子学与探测技术,2015,35(8):845-848.
[13] 刘易,侯会良,王明,等.核电子学电路仿真和数值分析综合实验方法[J].实验技术与管理,2016,33(11):143-146.
[14] 刘易,赵祥,周建斌,等.时域数值分析方法的核电子学仿真[J].实验室研究与探索,2016,35(9):96-100.